Skip to main content

Contract Information


Project Name SF 159 BROADUS SFTY IMPRV
Advertise Date 07/12/2018 04:00 PM
Close Date 08/06/2018 10:00 AM
Let Date 08/09/2018 09:00 AM

Notifications

No notifications found for this contract

Addendums

No addendums found for this contract

Clarifications

-1-
Submitted: Tuesday   24-JUL-2018 08:40 AM
Place classes Deck and Overlay-SF concrete with a temperature between 50 and 80 °F (10 and 26 °C). Place all other classes of concrete with a temperature between 50 and 85 °F (10 and 29 °C).

Questions

-1-
Submitted: Sunday    05-AUG-2018 06:03 PM  
Company: Montana Lines  
Contact: MTL  
How will the PVC Junction Box shown on the Beacon Mount Detail on Sheet E-3 be measured and paid?
Answer
Submitted: Monday 06-AUG-2018 11:12 AM
The cost of the PVC Junction Box shown on the Beacon Mount Detail on sheet E-3 is incidental to the 1.5" steel conduit.